WM2432HW/WM2032H*/WM1832CW
WM0532HW/WD-10210BD/WD-12210(5)BD
WM2444H*M/WM2442H*/WM2042CW
WM0642H*
If you press the START/PAUSE button when an error is displayed, any error except "PE" will disappear and the machine will go into the pause status.
In case of " PE, tE, dE " if the error is not resolved within 20 sec., or the in case of other errors,
if the error is not resolved within 4 min., power will be turned off automatically and the error code will blink. But in the case of "FE", power will not be turned off.
ERROR = WATER INLET ERROR
SYMTOM = I E
CAUSE = • Correct water level (2 level) is not reached within 8 minutes after water is supplied or it does not reach the preset water level within 25 minutes.
ERROR = IMBALANCE ERROR
SYMTOM = U E
CAUSE = • The load is too small.
• The appliance is tilted.
• Laundry is gathered to one side.
• Non distributable things are put into the drum.
ERROR = DRAIN ERROR
SYMTOM = 0 E
CAUSE = • Not fully drained within 10 minutes.
ERROR = OVER FLOW ERROR
SYMTOM = F E
CAUSE = • Water is overflowing (over 8 level).
¡ If "F E" is displayed, the drain pump will operate to the drain water automatically.
ERROR = PRESSURE SENSOR ERROR
SYMTOM = P E
CAUSE = • The SENSOR SWITCH ASSEMBLY is out of order.
ERROR = DOOR OPEN ERROR
SYMTOM = d E
CAUSE = • Door not all the way closed.
• Loose electrical connections at Door switch and
PWB Assembly.
• The DOOR SWITCH ASSEMBLY is out of order.
ERROR = HEATING ERROR
SYMTOM = t E
CAUSE = • The THERMISTOR is out order.
ERROR = OVER CURRENT ERROR
SYMTOM = C E
CAUSE = • MAIN PWB ASSEMBLY is out of order.
• Winding in the STATOR ASSEMBLY is short-circuited.
ERROR = LOCKED MOTOR ERROR
SYMTOM = L E
CAUSE = • The connector (3-pin, male, white) in the MOTOR HARNESS is not connected to the connector
(3-pin, female, white) of STATOR ASSEMBLY.
• The electric contact between the connectors (3-pin, male, white) in the MOTOR HARNESS
and 4-pin, female, white connector in the MAIN PWB ASSEMBLY is bad or unstable.
• The MOTOR HARNESS between the STATOR ASSEMBLY and MAIN PWB ASSEMBLY is cut (open
circuited).
• The hall sensor is out of order/defective.
ERROR = BALL SENSOR ERROR
SYMTOM = b E
CAUSE = • Loose Ball Sensor Connector.
• Ball Sensor is out of order.
¡ Displayed only when the START / PAUSE button is first pressed in the QC Test Mode.
ERROR = EEPROM ERROR
SYMTOM = E E
CAUSE = • EEPROM is out of order.
¡ Displayed only when the START / PAUSE button is first pressed in the QC Test Mode.
ERROR = POWER FAILURE
SYMTOM = P F
CAUSE = • The washer experienced a power failure.